An HTTP service for BetaBrite and Alpha protocol LED signs
1.4K
An HTTP service that drives a BetaBrite Classic sign, either through a serial cable or through an Ethernet to RS-232 adapter.
Several sources can share the sign at once. Each registers a named slot, and the sign rotates through the slots that are showing by itself. A slot can be hidden without being given up, so a message can be taken off the display and put back without being sent again, unless it was the last one showing. A variable is a value that messages call by name, such as a temperature, and changing it does not blank the sign or restart the message showing it. An alert takes the whole display over until it is released, after which the rotation resumes.
temperature while a doorbell
automation owns doorbell, without either knowing about the other.Outside <var:temp><degree>F calls
the variable temp, and a new value is one small write that the sign shows the next
time it draws the message, with no blank and no restart. One variable can appear in
any number of messages, and a value that stops arriving can be made to go stale./dev/ttyUSB0 or over
the network through an Ethernet to RS-232 adapter at socket://host:port.scripts/install.sh, or a container runtime, for
the published image. The service itself runs anywhere Python does; only the installer
is Linux specific.loop:// is pyserial's loopback, so the service will start and serve its API with
nothing attached. From a checkout:
pip install -e ".[dev]"
READERBOARD_SERIAL_URL=loop:// READERBOARD_API_KEY=dev-key \
READERBOARD_STATE_PATH=./state.json \
python -m readerboard
Or without one:
docker run --rm -p 5001:5001 \
-e READERBOARD_SERIAL_URL=loop:// -e READERBOARD_API_KEY=dev-key \
ghcr.io/mjaksn/readerboard:latest
Then open http://127.0.0.1:5001/docs.
loop:// swallows everything written to it, so the service runs but there is
nothing to see. To watch what it would have sent, run it against the sign
simulator in tools/signsim/ instead:
pip install --require-hashes -r tools/signsim/requirements.lock
python scripts/run_with_simulator.py
That starts the simulator and the service together, already pointed at each
other, and stops both on Ctrl+C. The simulator decodes each transmission, says
what every byte of it means, and shows what the sign would be holding as a
result. tools/signsim/README.md has the details.
From a checkout, with the sign on a cable or on an Ethernet to RS-232 adapter:
pip install -e ".[dev]"
pip install --require-hashes -r tools/apiclient/requirements.lock
python scripts/run_against_a_sign.py --serial-url socket://192.168.2.51:4001
That starts the service and the client together, with no simulator. The service
comes up on http://127.0.0.1:5001 with /docs beside it, the client comes up
pointed at that address, and the API key to paste into the client is printed in
the same window. --no-client leaves the client out. Ctrl+C stops everything,
and closing the client leaves the service running.
Both editors carry it as a launch configuration named "readerboard against the
real sign and the client". The sign's address is an argument in those, not a
setting in a file, so changing which sign is driven means editing the
Parameters field in PyCharm's run configuration dialog, or args in
.vscode/launch.json. They also pass --api-port 5002, so a second checkout of
this repository on the same machine can run beside them; the launcher checks
that port before it starts anything rather than letting the service bind, fail
and stop after the client has been pointed at whatever else answered.
It is a pyserial URL, and there is no slash between the host and the port.
socket://192.168.2.51/:4001 looks close enough to right and is not: pyserial
answers it with a bare TypeError from deep inside a connection attempt, naming
neither the setting nor the value. The launcher checks the address before it
opens anything and says which part is wrong. The four forms are:
socket://192.168.2.51:4001 an Ethernet to RS-232 adapter passing raw TCP
rfc2217://192.168.2.51:23 an adapter speaking the telnet serial protocol
COM3 a cable on Windows
/dev/ttyUSB0 a cable on Linux
Most adapters pass raw TCP, so try socket:// first. If the link opens but the
sign shows nothing or shows rubbish, and the adapter answers on port 23, it is
probably negotiating telnet rather than passing bytes through, and rfc2217://
is the form that speaks that.
The key is not an argument. A launch configuration is a tracked file and a
command line is a shell history, and anyone holding the key can write to the
sign. It lives in config.local.toml at the root of the checkout, which
.gitignore covers and which the launcher writes with a generated key the first
time it runs. Given no --serial-url, the address is read from there too.
Writing a memory configuration erases every message on the sign, and the service writes one whenever it has no record of the configuration already applied. The first run against a sign this machine has never driven therefore erases it, which is also the only way to allocate the files it then writes into. Every run after that reads the record and leaves the sign alone.
That record is .local-sign-state.json, and it belongs to this launcher alone.
scripts/run_with_simulator.py deletes its own .local-state.json on every
launch, because the simulator starts empty every time and the service has to
reconfigure it. If the two shared one file, a simulator session would throw the
sign's record away and the next run against the sign would erase it.
Two ways, which do the same job. Pick whichever suits the machine.
sudo scripts/install.sh --serial-url socket://192.168.2.51:4001
This creates a readerboard system user, builds a virtual environment in
/opt/readerboard, writes /etc/readerboard/config.toml with a freshly generated API key,
and enables the readerboard service. It prints the key once, and it is safe to run
again after pulling a new version: your config file and key are left alone.
sudo scripts/uninstall.sh removes the service and the program but keeps your config and
your registered messages, so reinstalling puts the sign back as it was. Add --purge to
remove those too.
The image is published to both registries on every release, for linux/amd64,
linux/arm64 and linux/arm/v7, so a Pi pulls the same tag an x86 server does.
docker run -d --name readerboard --restart unless-stopped -p 5001:5001 \
-e READERBOARD_SERIAL_URL=socket://192.168.2.51:4001 \
-e READERBOARD_API_KEY=YOUR-KEY \
-v readerboard-state:/var/lib/readerboard \
ghcr.io/mjaksn/readerboard:latest
packaging/docker-compose.yml is the same thing as a Compose file, with the settings
worth knowing about written out beside it.
The volume is what matters here. The registered messages are persisted to
/var/lib/readerboard, and without it the sign comes back empty after a restart rather
than putting back what was on it.
Every setting is available as an environment variable, so no config file is needed. Mount
one at /etc/readerboard/config.toml if you would rather have it, in the format
packaging/config.example.toml documents; the environment still wins over the file.
For a sign on a cable rather than on the network, the container needs the device passed
in and needs to be in the group that owns it. The group has to be given as a number,
because the container has no /etc/group entry for the host's dialout:
stat -c '%G %g' /dev/ttyUSB0 # 20 on Debian and Raspberry Pi OS, 18 on Fedora
docker run ... --device /dev/ttyUSB0 --group-add 20 \
-e READERBOARD_SERIAL_URL=/dev/ttyUSB0 ...
Every write needs an X-API-Key header, and so does GET /sign/information,
which asks the sign a question rather than reading the service's own record. The
service's other reads and GET /health do not. In the Swagger UI at /docs, the
Authorize button puts it in once for the whole page.
Register a message:
curl -X PUT http://localhost:5001/slots/temperature \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"message": "<green>18.4<degree> <red><time>", "display_mode": "HOLD"}'
Register a second one and the sign rotates between them:
curl -X PUT http://localhost:5001/slots/doorbell \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"message": "<amber>Someone at the door", "ttl_seconds": 300}'
Take a message off the display without giving up its slot, and put it back later:
curl -X PUT http://localhost:5001/slots/doorbell/active \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"active": false}'
A hidden message keeps its slot, its place in the order and its text, so showing it again
takes {"active": true} and no copy of what it said. Hiding or showing one is a single run
sequence write. That does disturb the display briefly, but far less than rewriting a
message does: enough less that it is easy to miss unless you are watching for it on a
static screen. The exception is the last message showing: its file is emptied as it goes,
because a sign whose run sequence names nothing freezes on what it was drawing, so
putting that one back costs the text as well as the sequence.
active is a field on the message endpoint too, where leaving it out is the point: a
source re-sending the same content every few minutes says nothing about it and so cannot
switch back on something that was deliberately hidden. Sending it moves the message.
A ttl_seconds can hide a message instead of deleting it, which suits anything that comes
back later, such as a bin day or a school notice:
curl -X PUT http://localhost:5001/slots/bins \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"message": "<green>BINS OUT TONIGHT", "ttl_seconds": 43200,
"delete_on_expiry": false}'
Put those together and a recurring notification is one call per event, sent in the same shape every time. This shows the alarm's state for a minute whenever it changes, then takes it off the rotation until the next one:
curl -X PUT http://localhost:5001/slots/alarm \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"message": "<red>ALARM NOW <var:arm_state>", "ttl_seconds": 60,
"delete_on_expiry": false, "active": true}'
The deadline clears itself as it hides the message, so each event gets a fresh minute rather than the message vanishing again on a deadline the last one left behind.
Show a live value. Create the variable first, then a message that calls it:
curl -X PUT http://localhost:5001/variables/temp \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"value": "72", "ttl_seconds": 1800, "stale_value": "--"}'
curl -X PUT http://localhost:5001/slots/weather \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"message": "Outside <var:temp><degree>F", "display_mode": "ROTATE"}'
From then on only the variable needs writing, and the message picks each new value up on its next pass across the sign.
Take the sign over for thirty seconds:
curl -X POST http://localhost:5001/alerts \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"message": "<red><flash_on>SMOKE ALARM", "ttl_seconds": 30}'
Make a noise, which is worth pairing with an alert if the sign is somewhere nobody is watching it:
curl -X POST http://localhost:5001/sign/command \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"command": "SOUND", "parameter": "BEEPS"}'
BEEPS is three short beeps and TONE is one continuous tone of about two seconds.
Those are the only two sounds there are: the sign has a fixed-pitch buzzer, so there
is no pitch or volume to choose.
Silence it with {"command": "SPEAKER", "parameter": "OFF"}, and turn it back on with
ON. That is a real mute: SOUND is still accepted and makes no noise. The setting
lives on the sign and survives a restart, so it is also the first thing to check if
SOUND ever seems to do nothing.
The full API is at /docs. Every markup token, value token, display mode and
control command is listed by the /enumerations reads there, which answer at
request time rather than being frozen into the description.
A message is plain text plus tokens written as <name>: <green>18.4<degree> is a
colour change, a number, and a degree symbol. GET /enumerations/markup-tokens lists
them all.
Text is encoded against the sign's own character table rather than as UTF-8, so café
displays correctly. A character the sign cannot render is rejected with a 400, as is an
unknown token: a write is told what the sign would have made of it rather than being
shown something it did not ask for.
A variable lives in a small file of its own on the sign, and a message or an alert
calls it with <var:name>. Writing a new value rewrites that file and nothing else,
which the sign takes without blanking, so a message showing a temperature or a count can
change every minute and never restart. In a scrolling mode the new value appears on the
message's next pass. An alert carrying a live wind speed works the same way, and keeps
the sign while the number changes.
A few things are worth knowing, all of them measured on the sign:
<red>DOWN turns the rest
of the message red as well, and so does a character set or a speed. If the text after
the call matters, set it again in the message after the call.<week_day> draws as a literal
9 from inside a variable, and a variable cannot call another. GET /enumerations/value-tokens lists what is allowed.11 and 88 are different widths and the text after them moves.
Put <fixed_width> in the message before the call and send values of the same length.
Fixed width also left-justifies the line.ttl_seconds and a stale_value
such as --, and once the time passes without a new value the sign shows the stale
value instead. The variable itself stays, since messages call it.variable_capacity bytes after
rendering, 32 by default. The sign does not cut an overlong value short, it empties it,
so the service refuses one rather than send it.A Home Assistant rest_command that keeps a sensor on the sign:
rest_command:
sign_temperature:
url: http://readerboard.local:5001/variables/temp
method: put
headers:
X-API-Key: !secret readerboard_key
content_type: application/json
payload: '{"value": "{{ value }}", "ttl_seconds": 1800, "stale_value": "--"}'
Call it from an automation triggered by the sensor, with the reading as value:
actions:
- action: rest_command.sign_temperature
data:
value: "{{ states('sensor.outside_temperature') | round(0) | int }}"
A sign mounted out of reach can wedge: a stray bit corrupts what its decoder is showing, it stops responding to writes, and there is no power switch within reach. There are two recoveries, and they are not interchangeable. Try the gentle one first.
A soft reset restarts the sign and erases nothing. The sign runs the same power-up diagnostics it runs when you plug it in, then carries on showing what it was showing. Its memory, its file table and its messages all survive; this was verified on the sign by reading them back either side of a reset.
curl -X POST http://localhost:5001/sign/command \
-H 'X-API-Key: YOUR-KEY' -H 'Content-Type: application/json' \
-d '{"command": "SOFT_RESET"}'
The call waits out the diagnostics before answering, so a 204 means the sign is listening again rather than that the bytes went out.
POST /sign/reboot is the escalation, and it is destructive. It clears the sign
outright, waits for it to restart, then re-pushes every message and the run sequence
from the service's own record, so the display still comes back to what it was.
curl -X POST http://localhost:5001/sign/reboot -H 'X-API-Key: YOUR-KEY'
Reach for it only when a soft reset was not enough. The sign is blank for twelve seconds
or more while it resets, longer with a lot of messages to put back. Neither is a way to
clear messages: DELETE /slots does that without resetting anything. The client
fronts the reboot with a warning-coloured confirmation for the same reason.
Settings come from /etc/readerboard/config.toml, overridden by environment variables
prefixed READERBOARD_. packaging/config.example.toml documents every one of them.
Every setting has both forms, and the container path relies on it: slot_count in the
file is READERBOARD_SLOT_COUNT in the environment. Under Docker the file is optional
and usually absent, which is not an error. READERBOARD_CONFIG_FILE moves the file if
you want it somewhere other than the default.
The sign's address is a full pyserial URL in serial_url: socket://192.168.2.51:4001
for an Ethernet to RS-232 adapter, rfc2217://192.168.2.51:23 for one speaking the
telnet serial protocol, /dev/ttyUSB0 or COM3 for a cable plugged straight in, or
loop:// to run the service with no sign attached. There is no slash between the host
and the port, and pyserial's answer to one that has a slash names neither the setting
nor the value.
Four settings reallocate the sign's memory when changed, and that erases every message
on it: slot_count, slot_capacity, variable_count and variable_capacity. The
service will do it, and say so loudly in the log, but they are not settings to fiddle
with. With variable_count at 0, variable_capacity allocates nothing, so changing it
alone reallocates nothing either.
An API key is required on every write, compared in constant time, and never logged.
GET /sign/information needs one too: it is a read of the sign itself rather than of the
service, so it sends a question over the wire, holds the sign until the answer arrives,
and reports the hardware's firmware and how full its memory is. The service's own reads
and GET /health need none, so a monitor can watch the slots without holding a key that
could write to them.
The key is declared to the API description as a security scheme, so the Swagger UI at
/docs has an Authorize button: enter the key once and everything on the page that
needs it carries it. It is the same X-API-Key header a client sends, so nothing about a script
or a Home Assistant rest_command changes.
That page is configured to remember the key, so it survives a reload or a browser
restart rather than needing to be pasted in again. Convenient on your own machine, and
worth knowing before you use Authorize on a shared or kiosk browser, where the next
person to open /docs inherits it. Use the browser's Logout in the Authorize dialog, or
just do not authorize there.
Message content reaches the sign as protocol bytes, so it is worth knowing what a client holding the key can do. The markup renderer emits bytes only for tokens it recognises and for characters in the sign's own table, so arbitrary control sequences cannot be injected through a message. What the holder of a key can do is display anything they like on your wall and set the sign's clock. There is nothing beyond the sign to reach: the service opens one serial link and touches nothing else.
Sensible precautions remain sensible:
/etc/readerboard/config.toml mode 0640. Anyone who can read it can write to the
sign.Under Docker the same points apply, with different mechanisms:
docker inspect on the container, and to anything that reads the Compose file's
environment. Mounting a config file mode 0640 keeps it out of both.-p 127.0.0.1:5001:5001, unless
clients on other machines need to reach it.--device gives the container that device and nothing
else. It does not need --privileged, and giving it that would hand it every device on
the host.pip install -e ".[dev]"
pytest
ruff check .
mypy readerboard
No sign is needed. The tests run against a capturing fake transport and against
pyserial's loop:// URL, so the real serial code path is exercised without hardware.
docs/protocol-notes.md records what the Alpha protocol actually says about the memory
configuration, the run sequence and the priority file, with the quotations that back each
claim. Read it before changing anything in readerboard/protocol/.
scripts/protocol_spike.py settles the few questions the document cannot answer about
this particular sign. It is destructive and refuses to run without --confirm-erase.